MITODERMENVersion: 2026-06-30
MitoPen E30-Ultima
Motorised auto-stamp meso pen — 5 speeds, adjustable depth
MitoPen E30-Ultima is a motorised auto-stamp meso pen: five speed settings, an adjustable-depth ring and click-in sterile needle cartridges. Available in a wireless variant with a built-in battery for chair-side mobility and a wired variant for high-volume rooms. Designed as the in-clinic delivery partner for the V-Tech serum and the Exosomes face system.
For professional use onlyKey facts
- 5 motorised speed settings, single-button switching
- Adjustable needle depth via the dial ring on the handle
- Sterile single-use click-in needle cartridges
- Wired and wireless (built-in battery) variants — 318 g handle
Key benefits
- Repeatable depth control
- The dial ring locks needle depth so the practitioner can move across zones without drifting off-protocol.
- Auto-stamp motor
- Five speeds let you tune cadence to the indication — slower on bony areas, faster on dense zones.
- Sterile click-in cartridges
- Sealed sterile cartridges click in and lock with a counter-clockwise twist; safer changeover between patients.
- Two variants
- Wireless model for chair-side mobility, wired model for back-to-back sessions in a busy room.
Active ingredients
- MitoPen E30-Ultima handle (318 g)
- 5 V / 1 A power adapter
- Power cable
- 2 sterile single-use needle cartridges
- User manual
Application protocol: Operating protocol
- Open a sterile cartridge from its packaging.
- Align the round slot to the 1–2 mark on the handle and slide horizontally to the stop.
- Lock the cartridge with a counter-clockwise twist; to remove, twist clockwise and pull straight out.
- Hold the power button 2–3 seconds to switch on. Press to step through the 5 speeds.
- Set needle depth: rotate the dial clockwise for shorter, counter-clockwise for longer.
- Treat one zone at a time; keep the handle upright so fluids do not flow back into the body of the device.
Safety & contraindications: Do not treat
- Patients with acute illness or a temperature above 38 °C.
- Patients with relevant allergies or haemophilia.
- Patients with facial melanosis.
- Patients with high internal body temperature or under regular hospital care.
- Patients on incompatible medication and patients under 12.
- Use only on a stable mains voltage (≠ 220 V AC); do not operate in extreme heat, dust or humidity.
Indications
V-Tech serum delivery · Post-procedure skin renewal · Scar and texture protocols · Pre-laser priming · Hair-loss scalp sessions with Exosignal Hair